features

MICROWAVE TYPE FLOW SENSOR KFD-1/KFD-2
Even one pellet is not overlooked!
High sensitivity and stability with 24 GHz power!
  • Even one pellet is not overlooked by our proprietary circuit.
  • It can permeate substances such as a glass and synthetic resin to enable indirect detection.
  • It is not easily affected by dirt and scale on the detected surface.
  • Both a minute flow and large amount of flow can be detected by adjusting the sensitivity.

operating principles

When a microwave emitted from the sensor touches the powders or granules flowing in the pipe, the reflected wave converts and amplifies the frequency drift according to the Doppler effect, and produces contact output.  

standard specification

Model   KFD-1
Power Source   105/210VAC ±10% 50/60Hz
Power Consumption   5VA
Detection Distance   max1.5m (depends on substance)
Type of Wave   NON
Frequency   24.2GHz
Radiation Power   5.5mW
Output Contact   SPDT 250VAC 5A
ALARM (option)   SPST 250VAC 5A
  (The instrument provides this output instantly on blackout
  or 6 seconds later a poor transmission intensity and abort.)
ON Delay   Max.10seconds (variable)
OFF Delay   Max.10seconds (variable)
Allowable Pressure   490kPa
Temperature   -10℃~+55℃
Enclosure Rating   IP-67

  • product

    • KFD-1
      Standard

In addition to the above, various specifications are available.
For more information, see respective catalogs or contact us by phone or mail.